• HV Detuned Reactors
Detuned Reactor

HV Detuned Reactors

Lafaelt dry-type iron-core hv reactor is mainly used in power systems below 35KV to be connected in series with high-voltage capacitor banks to form a high-voltage reactive power compensation device.

The coil adopts split cylinder type, multi-segment gap iron core pure dry structure, pure copper coil.

Moisture-proof, anti-corrosion, good fireproof.

Description

Advantages

Parameters

Selection

Download


Overview


The reactive power compensation device of automatic switching parallel capacitor bank is widely used in the hub substation to improve the power quality in the grid and the power factor of the transmission line, and reduce the circuit loss. The switching and operation of the reactive power compensation device raised the question of how to effectively reduce the inrush current multiple at the moment of closing in the capacitor and suppress the high-order harmonics in the capacitor


Lafaelt dry-type iron-core high-voltage reactor is mainly used in power systems below 35KV to be connected in series with high-voltage capacitor banks to form a high-voltage reactive power compensation device.

Advantages

The coil adopts split cylinder type, multi-segment gap iron core pure dry structure, pure copper coil, which will not cause the coil to age and crack, so as to facilitate the recycling of raw materials and reduce environmental pollution.


The coil, iron core, and insulating fasteners are firmly combined after double vacuum treatment with special solvent-free insulating varnish for the reactor and the insulating impregnated varnish for the outer covering.


The outer insulating paint has strong hydrophobicity, low partial discharge, and can operate safely in harsh environments for a long time.


The whole core is vacuum-impregnated with epoxy resin paint to ensure mechanical strength and reduce the noise level of the reactor more effectively.


Moisture-proof, anti-corrosion, good fireproof characteristics, and ducts are left to ensure good ventilation and heat dissipation performance.

Technical Parameter

Implement Standards

IEC60871/EN60871

Working Voltage

6~10kv

Rated Frequency

50/60Hz

Reactor Linearity

1.35ln

Normal Reactance

5%6%12%14%

Noise

<50dB

Inductance Deviation Ratio

The unbalance between reactors is ±3%, and the inductance error is -2 ~ +3%

Operation Evvironment

The temperature is -25°C~+40°C, and the  relative humidity should not exceed 90%. There should be good ventilation around, no harmful gas, no flammable and explosive items, no places with strong bumps and shock vibrations

Altitude

<2000m

Equipment Installation Matters

The inclination of the vertical installation of the equipment is not more than 15°


Common specification selection table of HV detuned reactor series

6KV HV Reactors

Dimensions (mm)

Mounting Hole

Reactance 6%

L

W

H

E

F

D/mm

LHDR6-9-6

800

400

760

560

300

14φ

LHDR6-12-6

800

400

760

560

300

14φ

LHDR6-18-6

800

450

820

560

350

14φ

LHDR6-24-6

900

450

870

660

350

14φ

LHDR6-30-6

900

500

900

660

350

14φ

LHDR6-36-6

950

500

900

660

400

14φ

LHDR6-54-6

1000

500

1000

700

400

14φ

LHDR6-60-6

1000

500

1000

700

400

14φ

LHDR6-72-6

1100

500

1050

740

400

14φ

LHDR6-90-6

1200

500

1050

820

400

18φ

LHDR6-108-6

1200

500

1050

820

400

18φ

Dimensional changes will not be notified, subject to the actual delivered products. If you have any questions, please contact Lafaelt.


   10KV HV Reactors

Dimensions (mm)

Mounting Hole

Reactance6%

L

W

H

E

F

D/mm

LHDR6-9-6

800

400

760

560

300

14φ

LHDR6-12-6

800

400

760

560

300

14φ

LHDR6-18-6

800

450

820

560

350

14φ

LHDR6-24-6

900

450

870

660

350

14φ

LHDR6-30-6

900

500

900

660

350

14φ

LHDR6-36-6

950

500

900

660

400

14φ

LHDR6-54-6

1000

500

1000

700

400

14φ

LHDR6-60-6

1000

500

1000

700

400

14φ

LHDR6-72-6

1100

500

1050

740

400

14φ

LHDR6-90-6

1200

500

1050

820

400

18φ

LHDR6-108-6

1200

500

1050

820

400

18φ

* Dimensional changes will not be notified, subject to the actual delivered products. If you have any questions, please contact Lafaelt.



HV Detuned Reactor Outside Drawing

HV Tuning Reactor Outside Drawing


Classify Title Download
back

Need Any Help

Leave your contacts and our engineers will help you to find the solution you are looking for.

Contact us for further information

The content with * is required

Related Products

0

Let s talk! We’ll provide the perfect solution for you!

Since its establishment, Lafaelt Electric has focused on comprehensive solutions for power quality and energy management. It has excellent quality in designing, researching, producing and manufacturing.

Copyright © 2022 Jiangsu Lafaelt Electric Co., Ltd.            Privacy Policy Powered by Bontop