It consists of Lafaelt capacitor bank, detuned reactors, power factor controllers, circuit breakers, fuses, contractors, lightning arresters, temperature controllers, fans, voltage ammeters, current transformer cabinets and other accessories
Multiple tuning frequencies can be selected to suppress 3rd, 5th or 7th orders harmonics, to protect the capacitors and prevent system resonance
When there are some harmonics in the grid, the tuning filter composed of capacitors and reactors in series should be used for reactive power compensation, so as to avoid the occurrence of resonance. It will not amplify but filter out some harmonics, and improve power factor at the same time. LRAC low-voltage static reactive power compensation device is the tuning compensation device switched by contractor.
The devices are mainly used in municipal buildings with air conditioners, energy-saving lamps and other equipment, such as schools, living quarters, etc. or industrial projects with stable current operation and no frequent load fluctuations, such as uninterrupted production factories, assembly line workshops, etc.
The device consists of Lafaelt capacitor bank, detuned reactors, power factor controllers, circuit breakers, fuses, contractors, lightning arresters, temperature controllers, fans, voltage ammeters, current transformer cabinets and other accessories.
Reasonable arrangement: the capacitors is placed below the reactors to prevent them from being affected by the reactors’ heating and extend their service lift.
Multiple tuning frequencies can be selected to suppress 3rd, 5th or 7th orders harmonics, to protect the capacitors and prevent system resonance.
International brand accessories: adopting high airflow fans, circuit breakers, contactors and other components from international famous manufactures like ABB, Schneider, and etc. to ensure the performance of the entire cabinet.
Split structure design: the layout inside the cabinet is neat and beautiful, which is good for ventilation and heat dissipation, prolongs its service life and is easy to install and maintain.
Strong universality: it covers various cabinet types such as GGD、GCK、GCS、MNS、OKKEN、BLOKSET、SIKUS、MODAN6000.
With rapid engineering experience: many typical cases with rapid experience, it can achieve perfect integration with low-voltage cabinets.
Precision and professional service: we supply personalized service, customized compensation scheme for special power distribution system (such as three-phase 200V system), perfectly solving reactive power compensation problems.
System voltage | 220V-750V 50Hz |
Rated capacity | 100 ~ 350kvar/cabinet (other capacity can be supplied according to needs) |
Tuning frequency | 134Hz,189Hz |
Protection class | IP20 (other class can be supplied according to needs) |
Installation site | Indoor |
Insulation level | 3kV/1min |
Discharge time | 50V/1min |
Temperature range | -5°C~+40°C (the 24-hour average maximum is 35°C, and the annual average maximum is 25°C) |
Manufacture standard | IEC60831, EN60439-1, GB/T15576-2008, JB/T9663-1999 |
Cabinet color | RAL7035 (other color can be supplied according to needs) |
The grouping scheme of low-voltage static reactive power compensation device
Switching by rated voltage 400V/50Hz contractor, in series with 7% filter reactor, with split-phase compensation, this is the typical combination scheme.
Power (kvar) | Combination Model | Loop Capacity (kvar) | Controller | Cabinet Size | ||||||||||
1a | 1b | 1c | 2a | 2b | 2c | 3 | 4 | 5 | 6 | 7 | W*H*D | |||
130 | LRTS480-130/6-7 | 10 | 10 | 10 | 25 | 25 | 50 | LPF230-12-W | 800*2200*1000 | |||||
195 | LRTS480-195/7-7 | 15 | 15 | 15 | 25 | 25 | 50 | 50 | LPF230-12-W | 1000*2200*1000 | ||||
240 | LRTS480-240/10-7 | 10 | 10 | 10 | 10 | 10 | 10 | 30 | 30 | 60 | 60 | LPF230-12-W | 1000*2200*1000 | |
300 | LRTS480-300/11-7 | 10 | 10 | 10 | 10 | 10 | 10 | 25 | 50 | 50 | 50 | 50 | LPF230-12-W | 1000*2200*1000 |
350 | LRTS480-350/11-7 | 15 | 15 | 15 | 15 | 15 | 15 | 30 | 60 | 60 | 60 | 60 | LPF230-12-W | 1000*2200*1000 |
480 | LRTS480-480/20-7 | 10 | 10 | 10 | 10 | 10 | 10 | 30 | 60 | 60 | 60 | LPF230-12-W | 2*800*2200*1000 |
Remark: when the reactive power compensation cabinet is a mixed compensation cabinet, in order to ensure heat dissipation, it is recommended to divide the single cabinet with capacity over 350kvar into main and auxiliary cabinets.
Series connected 14% filter reactor with split-phase compensation, the model is LRTS525-300/11-14、LRTS525-480/20-14 main and auxiliary cabinets.
Classify | Title | Download |
---|
Leave your contacts and our engineers will help you to find the solution you are looking for.
Hi! Welcome back.
How are you doing?
Let s talk! We’ll provide the perfect solution for you!
Since its establishment, Lafaelt Electric has focused on comprehensive solutions for power quality and energy management. It has excellent quality in designing, researching, producing and manufacturing.
Sales Center Add: 2nd Floor, No. 268, Tongxie Road, Changning District, Shanghai, China
Factory Add:No. 79, Qunxing Road, Xinwu District, Wuxi City, Jiangsu Province, China