• Low-voltage Static Reactive Power Compensation Device
Digital Capacitor Bank Cabinet

Low-voltage Static Reactive Power Compensation Device

It consists of Lafaelt capacitor bank, detuned reactors, power factor controllers, circuit breakers, fuses, contractors, lightning arresters, temperature controllers, fans, voltage ammeters, current transformer cabinets and other accessories

Multiple tuning frequencies can be selected to suppress 3rd, 5th or 7th orders harmonics, to protect the capacitors and prevent system resonance

Description

Advantages

Parameters

Selection

Download

Overview

When there are some harmonics in the grid, the tuning filter composed of capacitors and reactors in series should be used for reactive power compensation, so as to avoid the occurrence of resonance. It will not amplify but filter out some harmonics, and improve power factor at the same time. LRAC low-voltage static reactive power compensation device is the tuning compensation device switched by contractor.


Application

The devices are mainly used in municipal buildings with air conditioners, energy-saving lamps and other equipment, such as schools, living quarters, etc. or industrial projects with stable current operation and no frequent load fluctuations, such as uninterrupted production factories, assembly line workshops, etc.

The device consists of Lafaelt capacitor bank, detuned reactors, power factor controllers, circuit breakers, fuses, contractors, lightning arresters, temperature controllers, fans, voltage ammeters, current transformer cabinets and other accessories.


Reasonable arrangement: the capacitors is placed below the reactors to prevent them from being affected by the reactors’ heating and extend their service lift.


Multiple tuning frequencies can be selected to suppress 3rd, 5th or 7th orders harmonics, to protect the capacitors and prevent system resonance.


International brand accessories: adopting high airflow fans, circuit breakers, contactors and other components from international famous manufactures like ABB, Schneider, and etc. to ensure the performance of the entire cabinet.


Split structure design: the layout inside the cabinet is neat and beautiful, which is good for ventilation and heat dissipation, prolongs its service life and is easy to install and maintain.


Strong universality: it covers various cabinet types such as GGD、GCK、GCS、MNS、OKKEN、BLOKSET、SIKUS、MODAN6000.


With rapid engineering experience: many typical cases with rapid experience, it can achieve perfect integration with low-voltage cabinets.


Precision and professional service: we supply personalized service, customized compensation scheme for special power distribution system (such as three-phase 200V system), perfectly solving reactive power compensation problems.

Technical Parameters

System voltage

220V-750V 50Hz

Rated capacity

100 ~ 350kvar/cabinet (other capacity can be supplied according to needs)

Tuning frequency

134Hz,189Hz

Protection class

IP20 (other class can be supplied according to needs)

Installation site

Indoor

Insulation level

3kV/1min

Discharge time

50V/1min

Temperature range

-5°C~+40°C (the 24-hour average maximum is 35°C, and the annual average maximum is 25°C)

Manufacture standard

IEC60831, EN60439-1, GB/T15576-2008, JB/T9663-1999

Cabinet color

RAL7035 (other color can be supplied according to needs)


Typical configuration

The grouping scheme of low-voltage static reactive power compensation device

Switching by rated voltage 400V/50Hz contractor, in series with 7% filter reactor, with split-phase compensation, this is the typical combination scheme.


Power (kvar)

Combination Model

Loop Capacitykvar

Controller

Cabinet Size



1a

1b

1c

2a

2b

2c

3

4

5

6

7


W*H*D

130

LRTS480-130/6-7

10

10

10




25

25

50



LPF230-12-W

800*2200*1000

195

LRTS480-195/7-7

15

15

15




25

25

50

50


LPF230-12-W

1000*2200*1000

240

LRTS480-240/10-7

10

10

10

10

10

10

30

30

60

60


LPF230-12-W

1000*2200*1000

300

LRTS480-300/11-7

10

10

10

10

10

10

25

50

50

50

50

LPF230-12-W

1000*2200*1000

350

LRTS480-350/11-7

15

15

15

15

15

15

30

60

60

60

60

LPF230-12-W

1000*2200*1000

480

LRTS480-480/20-7

10

10

10

10

10

10

30

60

60

60


LPF230-12-W

2*800*2200*1000


Remark: when the reactive power compensation cabinet is a mixed compensation cabinet, in order to ensure heat dissipation, it is recommended to divide the single cabinet with capacity over 350kvar into main and auxiliary cabinets.

Series connected 14% filter reactor with split-phase compensation, the model is LRTS525-300/11-14、LRTS525-480/20-14 main and auxiliary cabinets.


Classify Title Download

Need Any Help

Leave your contacts and our engineers will help you to find the solution you are looking for.