High quality Lafaelt capacitors and detuned reactors can make sure long-term stable and reliable operation of the device.
Equipped with an interface to communicate with PC to realize distribution network automation.
It can realize fast real-time tracking and display of power factor, bus voltage and protection action signals.
High-voltage reactive power compensation devices are widely used in public utilities and large industries and mining enterprises in recent years. In a high-voltage system, the first step is to maintain the voltage at a certain level, at the same time it is necessary to compensate for the reactive power needs on the equipment side to reduce losses, so that customers can meet the relevant requirements proposed by the power supply department.
The hv devices are mainly used to improve the power factor of the grid, support system voltage, and suppress harmonics, reducing the harm of harmonics to the system.
High quality Lafaelt capacitors and detuned reactors can make sure long-term stable and reliable operation of the device and the design has a long service life.
Equipped with an interface to communicate with PC to realize distribution network automation.
It adopts the advanced automatic monitoring and control devices, always ensuring that the power factor of the compensated equipment is above 0.92, exempting fines caused by insufficient reactive power.
Equipped with a comprehensive monitoring and protection system, it has the function of monitoring, displaying, and protection fundamental voltage and current, and specialized anti resonance capability.
It can realize fast real-time tracking and display of power factor , bus voltage and protection action signals.
With perfect protection functions: quick-break protection, over-current protection, over-voltage and under-voltage protection, three-phase current imbalance protection.
System voltage | 1kV~10kV 50Hz |
Rated capacity | 100~5000kvar/cabinet (other capacity can be supplied according to needs) |
Tuning frequency | 134Hz、144Hz、204Hz、223Hz |
Protection class | IP40 (other class can be supplied according to needs) |
Installation site | Indoor |
Insulation level | Rated short-term power frequency withstand voltage 42kV, rated lightning impulse withstand voltage 75kV |
Discharge time | 75V/10min |
Temperature range | -5°C~+40°C (the 24-hour average maximum is 35°C, and the annual average maximum is 25°C) |
Manufacture standard | GB3906-2006, DL/T604-2009 |
Cabinet color | RAL7035 (Other color can be supplied according to needs) |
Installation site: indoor with no server mechanical vibration, harmful gas and vapors, conductive or explosive dust around.
Altitude height: ≦1000m
Environment temperature: -25°C~+45°C
Wind speed: less than 34m/s
Earthquake intensity: not exceeding level 8
Sunlight: amplitude not exceeding 0.1W/cm2
Relative humidity: daily average not exceeding 95%, monthly average not exceeding 90%
If any of the above conditions are not met, it will be considered a special usage environment, and special instructions should be given when ordering.
Classify | Title | Download |
---|
Leave your contacts and our engineers will help you to find the solution you are looking for.
Hi! Welcome back.
How are you doing?
Let s talk! We’ll provide the perfect solution for you!
Since its establishment, Lafaelt Electric has focused on comprehensive solutions for power quality and energy management. It has excellent quality in designing, researching, producing and manufacturing.
Sales Center Add: 2nd Floor, No. 268, Tongxie Road, Changning District, Shanghai, China
Factory Add:No. 79, Qunxing Road, Xinwu District, Wuxi City, Jiangsu Province, China